検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 120 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

A New application technique of a position-sensitive liquid light guide Cerenkov counter for the simultaneous position detection of $$^{90}$$Sr/$$^{90}$$Y and $$^{137}$$Cs radioactivity

寺阪 祐太; 瓜谷 章*

Nuclear Instruments and Methods in Physics Research A, 1049, p.168071_1 - 168071_7, 2023/04

 被引用回数:0 パーセンタイル:0.02(Instruments & Instrumentation)

A new application of a position-sensitive liquid light guide Cerenkov counter for the simultaneous position detection of $$^{90}$$Sr/$$^{90}$$Y and $$^{137}$$Cs radioactivity in a gamma-ray-dominant environment is proposed. $$beta$$-emitting $$^{90}$$Sr/$$^{90}$$Y and $$gamma$$-emitting $$^{137}$$Cs radioactive point sources were measured using a position-sensitive liquid light guide based on the time-of-flight (TOF) method. We found a clear difference in the count rate ratio between the source position peak and reflection peak of the position histogram. Moreover, simultaneous measurements of the radioactive point sources were performed. The results suggest that the source position and activity of $$^{90}$$Sr/$$^{90}$$Y and $$^{137}$$Cs can be simultaneously determined based on the count rate ratio of the source position peak and the reflection peak.

論文

Marking actinides for separation; Resonance-enhanced multiphoton charge transfer in actinide complexes

松田 晶平; 横山 啓一; 矢板 毅; 小林 徹; 金田 結依; Simonnet, M.; 関口 哲弘; 本田 充紀; 下条 晃司郎; 土井 玲祐; et al.

Science Advances (Internet), 8(20), p.eabn1991_1 - eabn1991_11, 2022/05

 被引用回数:6 パーセンタイル:58.16(Multidisciplinary Sciences)

fブロック元素は化学的性質が類似している。一方、それらの電子スペクトルではf電子準位間の光学遷移が明瞭に異なる。このf-f遷移波長での共鳴励起によって元素の酸化状態を制御することができれば、化学的な分離が難しいfブロック元素の精密分離技術が生まれる可能性がある。これまでに3つのランタノイド元素で共鳴多光子還元が観測されているが、アクチノイドでの共鳴多光子反応は報告例はなかった。本研究では硝酸水溶液においてアクチノイドの一つである三価アメリシウムの共鳴多光子電荷移動による光酸化を観測した。また、硝酸錯体が一次過程に寄与することが示唆された。

論文

Microanalysis of silica-based adsorbent for effective recovery of radioactive elements

佐野 雄一; 渡部 創; 松浦 治明*; 名越 航平*; 新井 剛*

Journal of Nuclear Science and Technology, 54(10), p.1058 - 1064, 2017/10

 被引用回数:5 パーセンタイル:37.06(Nuclear Science & Technology)

ポリマー架橋度が吸着材の吸着・溶離性能に与える影響についてポリマー架橋度をパラメータとした吸着材を用いた試験により評価するとともに、その要因をSTXM分析及びEXAFS分析により考察した。吸着材中に形成された金属錯体構造については、ポリマー架橋度により大きな違いは生じないことを確認した。一方、ポリマー架橋度の増加に伴いポリマーは細孔中に均一に広がる様子が認められるとともに、架橋度が高い条件では細孔が狭小化し、水分子が捕捉されやすくなるため、溶離率が低下するものと考えられた。

論文

Reliability estimation of neutron resonance thermometry using tantalum and tungsten

甲斐 哲也; 廣井 孝介; Su, Y. H.; 篠原 武尚; Parker, J. D.*; 松本 吉弘*; 林田 洋寿*; 瀬川 麻里子; 中谷 健; 及川 健一; et al.

Physics Procedia, 88, p.306 - 313, 2017/06

 被引用回数:4 パーセンタイル:85.09(Instruments & Instrumentation)

Neutron resonance thermometry, which measures material temperature by analyzing the Doppler broadening of a neutron resonance peak, is one of the applications of energy-resolved neutron imaging at RADEN of J-PARC. Although this technique is promising, advantages and disadvantages have not been discussed in practical applications. The authors measured neutron transmission rates of tantalum and tungsten foils in a heater chamber up to 300 degrees Celsius at RADEN. The energy-dependent neutron transmission rates with different statistics were obtained after the measurements by selecting arbitrary measuring intervals from one measurement, and the temperatures of the foils were estimated from those transmission rates with different statistics. The reliability of the neutron resonance thermometry with statistical accuracy, irradiation time and spatial resolution are discussed.

報告書

MVP/GMVP version 3; General purpose Monte Carlo codes for neutron and photon transport calculations based on continuous energy and multigroup methods

長家 康展; 奥村 啓介; 櫻井 健; 森 貴正

JAEA-Data/Code 2016-018, 421 Pages, 2017/03

JAEA-Data-Code-2016-018.pdf:3.89MB
JAEA-Data-Code-2016-018-appendix(CD-ROM).zip:4.02MB
JAEA-Data-Code-2016-018-hyperlink.zip:1.94MB

高速かつ高精度な中性子・光子輸送モンテカルロ計算を実現するため、日本原子力研究開発機構において、2つのモンテカルロコードMVP(連続エネルギー法)とGMVP(多群法)が開発されてきた。これらのコードはベクトル型アルゴリズムを採用し、ベクトル計算機用に開発されてきたが、標準並列化ライブラリーMPIを用いた並列計算にも対応しており、一般の計算機環境でもモンテカルロ計算の高速化が可能である。両コードは正確な物理モデル、詳細な幾何形状表現法、分散低減法等、実用コードとして十分な機能を有している。これらコードの第1版は1994年、第2版は2005年に公開され、それ以降も様々な改良と機能拡張が行われてきた。第2版公開以降の主な改良点と新機能は、(1)実効増倍率に対する摂動計算手法、(2)厳密共鳴弾性散乱モデル、(3)動特性パラメータ計算機能、(4)光核反応モデル、(5)遅発中性子のシミュレーション、(6)多群定数生成機能等である。本報告書では2つのコードで用いられている物理モデル、幾何形状表現法、新たな機能及びそれらの使用法が記載されている。

論文

Spectrum-dose conversion operator of NaI(Tl) and CsI(Tl) scintillation detectors for air dose rate measurement in contaminated environments

津田 修一; 斎藤 公明

Journal of Environmental Radioactivity, 166(Part 3), p.419 - 426, 2017/01

 被引用回数:27 パーセンタイル:65.77(Environmental Sciences)

東京電力福島第一原子力発電所事故後、福島県をはじめ東日本の広域において、環境中の空間線量率測定等が継続して実施されている。測定には、原子力発電所等で利用されるサーベイメータ等の測定器が使用され、それらは基準校正場と呼ばれる既知の放射線場において、一方向からの照射条件で線量の校正が行われている。しかし一般に、測定器は入射する放射線の方向によって異なる感度を有し、実際の環境中では、放射線は様々な方向から測定器に入射する。そこで本研究では、通常よく用いられるNaI(Tl)およびCsI(Tl)シンチレーション式測定器で得られる線量の光子入射方向依存性を評価するために、ほぼ無限に広がった地面に放射性核種が存在する環境をPHITSコード上で再現し、周辺線量当量に対する環境測定用のスペクトル-線量変換演算子(G(E)関数)を導出した。その結果、通常よく用いられるシンチレーション式測定器は、単色エネルギー光子の場合、線量を最大で約40%過大評価する可能性のあるものの、実際の環境中では+20%以内で環境線源に対する線量を再現することを明らかにした。

論文

Measurement of the $$^{77}$$Se($$gamma$$, n) cross section and uncertainty evaluation of the $$^{79}$$Se(n, $$gamma$$) cross section

北谷 文人; 原田 秀郎; 後神 進史*; 岩本 信之; 宇都宮 弘章*; 秋宗 秀俊*; 豊川 弘之*; 山田 家和勝*; 井頭 政之*

Journal of Nuclear Science and Technology, 53(4), p.475 - 485, 2016/04

 被引用回数:5 パーセンタイル:43.41(Nuclear Science & Technology)

We precisely measured the ($$gamma$$, n) cross section for $$^{77}$$Se by developing a spectroscopic method utilizing Laser Compton-Scattering $$gamma$$-rays. Moreover, the $$^{79}$$Se(n, $$gamma$$) $$^{80}$$Se cross section was deduced using the statistical model calculation code CCONE with $$gamma$$-ray strength functions adjusted to reproduce the ($$gamma$$, n) cross sections for $$^{77}$$Se and the even Se isotopes $$^{76}$$Se, $$^{78}$$Se and $$^{80}$$Se. The reliability of the $$^{79}$$Se(n, $$gamma$$) $$^{80}$$Se cross section calculated by CCONE with the adjusted $$gamma$$-ray strength function was evaluated by comparing available experimental (n, $$gamma$$) cross sections for stable $$^{76, 77}$$Se isotopes and those calculated by CCONE with the adjusted $$gamma$$-ray strength function. The result provides fundamental data for the study of nuclear transmutation for the long-lived fission product of $$^{79}$$Se.

論文

Activation and control of visible single defects in 4H-, 6H-, and 3C-SiC by oxidation

Lohrmann, A.*; Castelletto, S.*; Klein, J. R.*; 大島 武; Bosi, M.*; Negri, M.*; Lau, D. W. M.*; Gibson, B. C.*; Prawer, S.*; McCallum, J. C.*; et al.

Applied Physics Letters, 108(2), p.021107_1 - 021107_4, 2016/01

 被引用回数:38 パーセンタイル:82.81(Physics, Applied)

Creation and characterisation of single photon emitters near the surface of 4H- and 6H-silicon carbide bulk substrates and 3C-SiC epitaxially grown on silicon substrates were investigated. These single photon emitters can be created and stabilized by thermal annealing in an oxygen atmosphere at temperatures above 550 $$^{circ}$$C. Hydrofluoric acid (HF) treatment is shown to effectively annihilate the emission from defects and to restore an optically clean surface. However, the emission from the defects can be obtained after re-oxidation above 550 $$^{circ}$$C. By measuring using standard confocal microscopy techniques, the excited state lifetimes for the emitters are found to be in the nanosecond regime in all three polytypes, and the emission dipoles are aligned with the lattice.

論文

Defect engineering in silicon carbide; Single photon sources, quantum sensors and RF emitters

Kraus, H.; Simin, D.*; Fuchs, F.*; 小野田 忍; 牧野 高紘; Dyakonov, V.*; 大島 武

Proceedings of 11th International Workshop on Radiation Effects on Semiconductor Devices for Space Applications (RASEDA-11) (Internet), p.176 - 179, 2015/11

Quantum centers in silicon carbide (SiC) have already transcended their former reputation as mere performance-hampering defects. Especially the silicon vacancies, but also other point defects offer a variety of quantum applications, completing and complementing the successful NV centers in diamond. We aim to provide an overview over the research activities on quantum centers in silicon carbide, from fundamental knowledge on the 3/2 spin multiplicity, over microwave emission and single photon sources, to axis-aware magnetic field sensing and temperature sensing. Finally, we discussed creating tailored defects in SiC using different radiation parameters.

論文

Room temperature quantum emission from cubic silicon carbide nanoparticles

Castelletto, S.*; Johnson, B. C.*; Zachreson, C.*; Beke, D.*; Balogh, I.*; 大島 武; Aharonovich, I.*; Gali, A.*

ACS Nano, 8(8), p.7938 - 7947, 2014/08

 被引用回数:85 パーセンタイル:90.49(Chemistry, Multidisciplinary)

Single Photon Sources (SPSs) in cubic (3C) Silicon Carbide (SiC) Nano Particles (NPs) were investigated. As a result, photo luminescence (PL) with broad emission at wavelength ranges between 600 and 800 nm was observed from 3C-SiC NPs at room temperature. The second order photon auto-correlation measurements revealed that defect with the PL characteristic is SPSs. The intensity and stability of the PL increased when samples were irradiated with electrons and subsequently annealed at 500 $$^{circ}$$C. From PL measurements at low temperature and theoretical analysis using spin-polarized density functional theory, the defect can be identified as carbon-antisite carbon-vacancy pair (C$$_{Si}$$V$$_{C}$$).

論文

Study of radiation-induced primary process by ion pulse radiolysis

吉田 陽一*; Yang, J.*; 近藤 孝文*; 関 修平*; 古澤 孝弘*; 田川 精一*; 柴田 裕実*; 田口 光正; 小嶋 拓治; 南波 秀樹

JAEA-Review 2005-001, TIARA Annual Report 2004, p.183 - 185, 2006/01

シングルフォトンカウンティングシステムを用いて重イオンパルスラジオリシス技術を開発した。このシステムでは、溶液試料入射前に置かれた薄膜シンチレータにイオンを照射した時にシンチレータから発した光を溶液試料中に生成する初期活性種の検出光源として用いた。このシステムを用いて水中における水和電子の時間過渡吸収の測定が達成でき、これにより本技術の有用性が示された。

論文

Comparison of synchrotron radiation calculations between analytical codes(STAC8,PHOTON) and Monte Carlo codes (FLUKA,EGS4)

Liu, J. C.*; Fasso, A.*; Prinz, A.*; Rokni, S.*; 浅野 芳裕

Radiation Protection Dosimetry, 116(1-4), p.658 - 661, 2005/12

 被引用回数:6 パーセンタイル:40.47(Environmental Sciences)

筆者が開発したSTAC8コードをSLAC, SSRLビームラインに適用した場合の解析結果をFLUKAやEGS4及びPHOTONと比較し、その有効性を実証した。また、STAC8コードの計算機能のうちでダブル散乱線評価やミラー反射による放射光計算の有効性についても議論する。

論文

Calculations for the availability of photoneutron using synchrotron radiation

浅野 芳裕; 川島 祥孝*

Radiation Protection Dosimetry, 115(1-4), p.176 - 180, 2005/12

 被引用回数:0 パーセンタイル:0.01(Environmental Sciences)

磁場強度10Tの超伝導ウィグラーと8GeV蓄積リングから発生する放射光をBeターゲットに照射して得られる光核反応中性子強度を評価するとともに、熱中性子利用の立場から遮蔽,減速装置を概念設計するとともに実験位置で得られる強度を既設設備と比較した。

論文

Development of lung and soft tissue substitutes for photons

木名瀬 栄; 木村 雅哉*; 野口 宏; 横山 須美

Radiation Protection Dosimetry, 115(1-4), p.284 - 288, 2005/12

 被引用回数:10 パーセンタイル:56.74(Environmental Sciences)

著者らは、これまで人体の骨格について密度や線減弱係数が等価な骨格組織等価材を開発するとともに頭部ファントムを製作した。本研究では、 さらに、 呼吸気道部等を表現するのに必要な人体の肺,軟組織,筋肉,筋肉+10パーセント脂肪,軟骨,喉頭,気管,甲状腺,腎臓,肝臓,皮膚,脳について、それぞれの組織等価材を開発した。また、それぞれの組織等価材は、実測により光子減弱特性を評価した。

論文

Shielding analysis at the upper section of the accelerator-driven system

佐々 敏信; Yang, J. A.*; 大井川 宏之

Radiation Protection Dosimetry, 116(1-4), p.256 - 258, 2005/12

 被引用回数:0 パーセンタイル:0.01(Environmental Sciences)

加速器駆動システム(ADS)の陽子ビームダクトは核破砕中性子や光子のストリーミング経路となり、これにより未臨界炉心上部に配置された電磁石などの機器の放射化を誘発する恐れがある。この放射化量を定量的に評価することを目的に、鉛ビスマス冷却ADS(800MWt)のストリーミング解析を実施した。MCNPXを使用してビームダクトからの漏洩中性子と光子の放射線量を求めた。二次光子の解析は、多くのマイナーアクチニド断面積を$$gamma$$線生成断面積が定義されているプルトニウムに置き換えて実施した。ビームダクトからストリーミングした中性子により、ビームダクト上部の線量は、上部プラグの他の部分より20桁多い線量を与えることがわかった。MCNPXの解析で得られた漏洩粒子スペクトルを使用したDCHAIN-SPによる解析では、電磁石と遮蔽プラグが高い放射能を有することがわかった。

報告書

第6回光量子科学研究シンポジウム論文集; 2004年11月4日-5日,木津

関西研究所

JAERI-Conf 2005-004, 243 Pages, 2005/06

JAERI-Conf-2005-004.pdf:16.74MB

第6回光量子科学研究シンポジウムが、平成16年11月4日,5日の両日、日本原子力研究所関西研究所(木津地区)において開催された。本論文集は、同シンポジウムにおいて行われた招待講演5件を含む講演16件,平成15年度実施した光量子科学に関する協力研究・共同研究課題発表を含むポスター発表56件のうち、論文として投稿された58件を収録している。

報告書

MVP/GMVP 2; General purpose Monte Carlo codes for neutron and photon transport calculations based on continuous energy and multigroup methods

長家 康展; 奥村 啓介; 森 貴正; 中川 正幸

JAERI 1348, 388 Pages, 2005/06

JAERI-1348.pdf:2.02MB

高速かつ高精度な中性子・光子輸送モンテカルロ計算を実現するため、2つのベクトルモンテカルロコードMVPとGMVPが日本原子力研究所において開発されている。MVPは連続エネルギー法、GMVPは多群法に基づいている。これらのコードはベクトル計算機上において、既存のスカラーコードに比べて10倍以上の高速化を実現している。両コードは正確な物理モデル,詳細な幾何形状表現法,分散低減法等、実用コードとして十分な機能を有している。これらコードの第1版は1994年に公開され、これまで広範囲にわたって改良及び新機能の追加がなされてきた。主な改良点と新機能は(1)ENDF-6形式のファイル6を用いて表現された散乱モデルへの対応,(2)時間依存タリー,(3)ポイントワイズ応答関数を用いた反応率計算,(4)柔軟な線源の指定,(5)任意温度における連続エネルギー計算,(6)固有値問題における分散のバイアス評価,(7)点検出器及び面検出器評価法,(8)確率論的幾何形状モデル,(9)炉雑音解析機能等である。本報告書では2つのコードで用いられている物理モデル,幾何形状表現法,新たな機能及びそれらの使用法が記載されている。

論文

JENDL photonuclear data file

岸田 則生*; 村田 徹*; 浅見 哲夫*; 小迫 和明*; 真木 紘一*; 原田 秀郎*; Lee, Y.*; Chang, J.*; 千葉 敏; 深堀 智生

AIP Conference Proceedings 769, p.199 - 202, 2005/05

光核反応に対する核データは、高エネルギー電子加速器の遮蔽設計及び高エネルギー$$gamma$$線治療の分野に必要である。JENDL光核反応データファイルは、シグマ委員会の光核反応データ評価ワーキンググループによって整備された。われわれは多くの文献サーベイから、評価に必要な十分な実験データが圧倒的に不足しているので、光核反応データファイルを実験データのみから作成するのは困難であるという結論を得た。したがって、評価は統計模型核反応モデルの助けを借りて実施した。JENDL光核反応データファイルに格納される断面積データ等の物理量は、光吸収断面積,中性子,陽子,重陽子,三重陽子,$$^{3}$$He粒子,$$alpha$$粒子の収量及び二重微分断面積,同位体生成断面積である。アクチノイド核種に対しては、これに光核分裂断面積を加える。格納される$$^{2}$$Hから$$^{237}$$Npまでの68核種に対する最大光子入射エネルギーは140MeVである。

論文

Neutron cross-section evaluations for $$^{70,72,73,74,76}$$Ge

岩本 修; Herman, M.*; Mughabghab, S. F.*; Oblozinsk$'y$, P.*; Trkov, A.*

AIP Conference Proceedings 769, p.434 - 437, 2005/05

ゲルマニウム同位体に対する新たな評価を、熱エネルギーから20eVの中性子に対して行った。光子の生成に特に注目した。共鳴領域で以前の評価と比較し、大きな改善が行われた。高速中性子領域の評価に計算コードEMPIRE-2.19を使用した。鉄及びニオブに対する計算を通じて、光子生成の妥当性の検証を行った。また、同位体の評価値から天然元素データを構成し、天然ゲルマニウムの実験データと比較を行った。光子生成に関するさまざまな量を示し、中性子入射エネルギーに対する強い依存性について議論を行う。

報告書

Annual report of Kansai Research Establishment 2003; April 1, 2003 - March 31, 2004

関西研究所

JAERI-Review 2004-030, 150 Pages, 2005/02

JAERI-Review-2004-030.pdf:11.32MB

本報告書は、日本原子力研究所関西研究所の第5号の年報であり、2003年4月1日から2004年3月31日までの期間(平成15年度)に行われた光量子科学研究センター及び放射光科学研究センターの研究活動をまとめたものである。

120 件中 1件目~20件目を表示